Select Timer by Function

Delay on Make -- Timing Modules

All popular modes of operation are available in this group of totally solid state timing modules. They contain no moving parts, so 100 million operations is typical. They are encapsulated to protect their analog or digital solid state circuitry. A large selection of time delay ranges are available; knob or switch adjustment, external adjustment, or factory fixed time delays can be ordered.

Click on product name to see overview of product.

General Use -- Single Voltage, Surface mount with one screw or most can use the P1023-20 DIN rail adaptor.

Analog Timing, 1A Steady State Normally Open

TS1, Factory Fixed or External Adjust, 0.05 to 600 seconds

Analog Timing, 1A Steady State Normally Closed

TS4,Factory Fixed or External Adjust, 0.05 to 600 seconds

Analog Timing,1A Steady State Normally Open, Universal Voltage

TMV, 24 to 240VAC/DC, Knob Adjustable, 0.1 to 8 minutes
TSU,24 to 240VAC/DC, External Adjustment, 5 to 480 seconds

Analog Timing,0.5A Steady State Normally Open, PC Board or Surface Mount

MSM, Factory Fixed, 0.05 to 180 seconds

Digital Timing,1A Steady State Normally Open

KSD1, Factory Fixed or External Adjust, 0.1 to 500 minutes
TSD1, Factory Fixed or External Adjust, 0.2 second to 166 hours

Digital Timing,1A Steady State Normally Closed

KSD4, Factory Fixed or External Adjust, 0.1 second to 500 minutes
TSD4, Factory Fixed or External Adjust, 0.2 second to 166 minutes

Digital Timing,1A Steady State Normally Open, Universal Voltage

KSDU, 24 to 240VAC/DC in 2 ranges, Factory Fixed, 0.1 second to 2.8 hours
TDU, 24 to 277VAC/DC in 2 ranges, Switch Adjustment, 0.1 second to 2.8 hours

ProgramaCube Microcontroller, 1A Steady State

                    KSPS, Single Voltage, Knob, External Adjust, or Fixed, 0.1 second to 1000 hours
                    KSPU, Single Voltage, Switch Adjustment, 100 ms to 1023 hours

High Power --Single AC Voltage, Must be surface mounted to a metal surface with one #8 or #10 screw for proper heat dissipation.

Analog Timing,6A, 10A, or 20A Normally Open

TH1, Factory Fixed or External Adjust, 0.1 to 600 seconds

Digital Timing>, 6A, 10A, or 20A Normally Open

THD1, Factory Fixed or External Adjust, 0.1 second to 1000 minutes
THDM, Factory Fixed or External Adjust, 1 second to 1000 minutes

Digital Timing,6A, 10A, or 20A Normally Closed

THD4, Factory Fixed or External Adjust, 0.1 second to 1000 minutes

ProgramaCube Microcontroller, 6A, 10A, or 20A Steady State

NHPS, Single Voltage, Switch Adjustment, 0.1 second to 1000 hours
NHPU, Single Voltage, Switch Adjustment, 100 ms to 1000 hours

DIN Rail Mount, Digital Timing

ASQU, 24-240VAC/9-110VDC, 0.7A Steady State, Delays from 0.1 s to 100 m, 17.5 mm wide
ASTU
, 24-240VAC/9-110VDC, 0.7A Steady State, Delays from 0.1 s to 100 m, 17.5 mm Wide
DSQU
, 24-240VAC/9-110VDC, 0.7A Steady State, Delays from 0.1 s to 63 m, 17.5 mm Wide
DSTU, 24-240VAC/9-110VDC, 0.7A Steady State, Delays from 0.1 s to 63 m, 17.5 mm Wide