Delay on Make
-- Timing Modules
All popular modes of
operation are available in this group of totally solid state timing
modules. They contain no moving parts, so 100 million operations is
typical. They are encapsulated to protect their analog or digital solid
state circuitry. A large selection of time delay ranges are available;
knob or switch adjustment, external adjustment, or factory fixed time
delays can be ordered.
Click
on product name to see overview of product.
General Use
-- Single Voltage, Surface mount with
one screw or most can use the P1023-20
DIN rail adaptor.
-
Analog
Timing, 1A Steady State Normally Open
- TS1, Factory
Fixed or External Adjust, 0.05 to 600 seconds
-
Analog Timing, 1A Steady State Normally Closed
- TS4,Factory
Fixed or External Adjust, 0.05 to 600 seconds
-
Analog
Timing,1A Steady State Normally Open,
Universal Voltage
- TMV,
24 to 240VAC/DC, Knob Adjustable, 0.1 to 8 minutes
TSU,24 to
240VAC/DC, External Adjustment, 5 to 480 seconds
-
Analog
Timing,0.5A Steady State Normally
Open, PC Board or Surface Mount
-
- MSM,
Factory Fixed, 0.05 to 180 seconds
-
Digital
Timing,1A Steady State Normally Open
-
- KSD1,
Factory Fixed or External Adjust, 0.1 to 500 minutes
- TSD1,
Factory Fixed or External Adjust,
0.2 second to 166 hours
-
Digital
Timing,1A Steady State Normally Closed
- KSD4,
Factory Fixed or External Adjust, 0.1 second to 500 minutes
- TSD4,
Factory Fixed or External Adjust, 0.2 second to 166 minutes
-
Digital
Timing,1A Steady State Normally
Open, Universal Voltage
- KSDU,
24 to 240VAC/DC in 2 ranges, Factory Fixed,
0.1 second to 2.8 hours
TDU, 24
to 277VAC/DC in 2 ranges, Switch Adjustment, 0.1 second
to 2.8 hours
ProgramaCube Microcontroller, 1A
Steady State
KSPS, Single Voltage, Knob, External Adjust, or Fixed, 0.1
second
to 1000 hours
KSPU, Single Voltage, Switch Adjustment,
100 ms to 1023 hours
- High Power --Single AC Voltage,
Must be surface mounted to a metal surface with one #8 or #10 screw
for proper heat dissipation.
-
Analog
Timing,6A, 10A, or 20A Normally Open
-
TH1, Factory Fixed or External
Adjust, 0.1 to 600 seconds
-
Digital
Timing>, 6A, 10A, or 20A Normally Open
-
THD1, Factory Fixed or External Adjust, 0.1 second to 1000 minutes
THDM, Factory
Fixed or External Adjust, 1 second to 1000 minutes
-
Digital
Timing,6A, 10A, or 20A Normally Closed
-
THD4, Factory Fixed or
External Adjust, 0.1 second to 1000 minutes
-
ProgramaCube Microcontroller,
6A, 10A, or 20A Steady State
-
NHPS, Single Voltage, Switch
Adjustment, 0.1 second to 1000 hours
NHPU, Single Voltage, Switch
Adjustment, 100 ms to 1000 hours
DIN Rail Mount, Digital Timing
- ASQU, 24-240VAC/9-110VDC,
0.7A Steady State, Delays from 0.1 s to 100 m, 17.5 mm wide
ASTU, 24-240VAC/9-110VDC, 0.7A Steady State, Delays from 0.1
s to 100 m, 17.5 mm Wide
DSQU, 24-240VAC/9-110VDC, 0.7A Steady State, Delays from 0.1
s to 63 m, 17.5 mm Wide
DSTU, 24-240VAC/9-110VDC,
0.7A Steady State, Delays from 0.1 s to 63 m, 17.5 mm Wide
|