New Products PageProgramaCube eBrochureMotor Protectors eBrochureProduct Press ReleasesTimer Function Selection GuideTimer Function IndexTVW Compact 3 Phase Motor Protectors  LLC8 Series Low Liquid Level CutoffTVW/TVM Series Phase Monitors  ProgramaCube Time Delay RelaysProgramaCube Timing Modules  TCSA - AC Current Transducer

 

ABB SSAC Sitemap
Contact Us, Launch Email
ABB SSAC Home
Search by Part Number


Low Voltage Products & Systems

Search

ABB SSAC New Products


New Products:
KRPD/KRPS -- ProgramaCube® Compact, Time Delay Relay
KSPD/KSPS -- ProgramaCube®  Compact Timing Modules
KSPU/NHPU -- ProgramaCube®  Compact Timing Modules
HSPZ -- ProgramaCube®Dual Switch Adjustable
HLMU -- Isolated DPDT Universal 3 Phase Voltage Monitor
HLV -- Single Phase Undervoltage Monitor
TCSA -- AC Current Transducer
LLC8 -- Liquid Level Control -- Low Level Cutoff


KRPD Data Sheet
KRPS Data Sheet
KRPD,KRPS Series
ProgramaCube® Timing Module
  • In Stock, Factory Programmed, Shipped Fast
  • Choose 1 of 12 Dual Functions (KRPD)
  • Choose 1 of 13 Standard Functions (KRPS)
  • Special Time Ranges and Functions Available
  • Microcontroller Circuitry, +/-0.5% Repeat Accuracy
  • Isolated 10 A SPDT Output Contacts
  • Onboard, External Adjust or Fixed Time Delays
  • 12 to 240 V in 2 Ranges
  • Delays from 100 ms to 1000 h in 9 Ranges
  • 0.25 in. (6.35 mm) Male Quick Connect Terminals
  • Surface Mount with One #10 (M5 x 0.8) Screw
  • 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
  • UL Recognized, CSA Certified, CE

KSPD Data Sheet
KSPS Data Sheet
KSPD,KSPS Series
ProgramaCube® Timing Module

  • In Stock, Factory Programmed, Shipped Fast
  • Choose 1 of 12 Dual Functions (KSPD)
  • Choose 1 of 12 Standard Functions (KSPS)
  • Special Time Ranges and Functions Available
  • Microcontroller Circuitry, +/-0.5% Repeat Accuracy
  • Solid State Output 1 Amp Steady, 10 Amps Inrush
  • Onboard, External Adjust, or Fixed Time Delay
  • 12 to 240 V in 3 Ranges
  • Delays From 100 ms to 1000 h in 9 Ranges
  • 0.25 in. (6.35 mm) Male Quick Connect Terminals
  • Surface Mount with One #10 (M5 x 0.8) Screw
  • 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
  • UL Recognized, CSA Certified, CE

KSPU Data Sheet
NHPU Data Sheet
KSPU/NHPU Series
ProgramaCube® Timing Modules

  • In Stock, Factory Programmed, Shipped Fast
  • Choose 1 of 14 Standard Functions
  • Special Time Ranges and Functions Available
  • Microcontroller Circuitry, +/-0.1% Repeat Accuracy
  • Soild State Output 1 Amp Steady, 10 Amps Inrush
  • Accurate Switch Adjustment
  • KSPU -- 12 to 240 V in 3Ranges 
  • NHPU -- 24 to 240 V AC
  • Delays from 100 ms to 1023 h  
  • 0.25 in. (6.35 mm) Male Quick Connect Terminals
  • Surface Mount with One #10 (M5 x 0.8) Screw
  • 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
  • UL Recognized, CSA Certified, CE

HSPZ Data Sheet
HSPZ Series
Timing Module

  • In Stock, Factory Programmed, Shipped Fast
  • Choose 1 of 13 Standard Functions
  • Special Time Ranges and Functions Available
  • Microcontroller circuitry +/-0.1% Repeat Accuracy
  • Solid State Output, 1 A Steady, 10 Amps Inrush
  • Accurate Switch Adjustment
  • 12 ... 240 V in 3 Ranges
  • Delays from 100 ms ... 1023 h in 6 ranges
  • Counts to 1023 in 2 Ranges
  • 2 x 3 x 1.51 in. (50.8 x 76.7 x 38.1 mm)

HLMU Data Sheet
HLMU Series
Universal Three Phase Voltage Monitor
  • Protects Against: Phase Loss, Phase Reversal, Over, Under & Unbalanced Voltages, Over/Under Frequency Encapsulated Circuitry
  • DPDT Isolated 10 A Contacts
  • Adjustable Trip Delay and Restart Delays
  • LED Indicates Relay Status, Faults, & Time Delays
  • Universal Line Voltage 200 ... 480 V AC in One Unit
  • Finger-Safe Terminal Blocks, up to 12 AWG
  • ASME A17.1 rule 210.6
  • NEMA MG1 14:30, 14:35
  • IEEE C62.41-1991 Level B
  • 2 x 3 x 1.51 in. (50.8 x 76.7 x 38.1 mm)
  • DIN Rail Mounting with Adaptor

HLV Data Sheet
HLV Series
Single Phase Undervoltage Monitor
  • Protects against undervoltage in Single Phase Systems
  • 30 A SPDT N.O. Output Contacts
  • 100 ... 240 VAC Input Voltage
  • 70 ... 220 VAC Adjustable Undervoltage Trip Points in 2 Ranges
  • Restart Delays from 3 ... 300 s
  • Trip Delay 1 ... 20 s Fixed
  • Isolated or Non Isolated Relay Contacts
  • UL Recognized, CSA Certified, CE
  • 3 x 2 x 1.5 in. (76.7 x 51.3 x 38.1 mm)
  • DIN Rail Mounting with Adaptor

LLC8 Data Sheet
LLC8 Series
Liquid Level Control / Low Level Cutoff

  • Designed for Low Level Cutoff Protection
  • Energized on Wet Probe
  • Fixed Time Delay of 1 to 60 seconds
  • Fixed Sense Resistance of 5k to 250k Ohms
  • 24, 120, or 230 V AC Input Voltages Available
  • Isolated 10 A, SPDT Relay Contacts 
  • Open PC board with 0.25 in (6.35 mm) Male Quick Connect Terminals
  • 2.5 x 2.19 x 1.88 Inches (63.5 x 55.6 x 47.8 mm)
  • UL Recognized, CSA Certified, CE

TCSA Data Sheet
TCSA Series
Loop Powered AC Current Transducer

  • Monitors 0 ...50 A in 4 Ranges
  • Loop Powered from 10 ... 30 V DC
  • Linear Output from 4 ... 20 mA
  • Zero and Span Adjustments
  • Complete Isolation Between Sensed Current and Control Circuit
  • 2 x 2 x 1.75 in. (50.8 x 50.8 x 44.5 mm)
  • UL Recognized, CSA Certified